Sponsored Links

Selasa, 07 November 2017

Sponsored Links

Phlebotomy Procedure - E Phlebotomy Training
src: jbohnert.files.wordpress.com

In medicine, venipuncture or venepuncture is the process of obtaining intravenous access for the purpose of intravenous therapy or for blood sampling of venous blood. In healthcare, this procedure is performed by medical laboratory scientists, medical practitioners, some EMTs, paramedics, phlebotomists, dialysis technicians, and other nursing staff. In veterinary medicine, the procedure is performed by veterinarians and veterinary technicians.

Venipuncture is one of the most routinely performed invasive procedures and is carried out for any of five reasons:

  1. to obtain blood for diagnostic purposes;
  2. to monitor levels of blood components (Lavery & Ingram 2005);
  3. to administer therapeutic treatments including medications, nutrition, or chemotherapy;
  4. to remove blood due to excess levels of iron or erythrocytes (red blood cells); or
  5. to collect blood for later uses, mainly transfusion either in the donor or in another person.

Blood analysis is an important diagnostic tool available to clinicians within healthcare.

Blood is most commonly obtained from the superficial veins of the upper limb. The median cubital vein, which lies within the cubital fossa anterior to the elbow, is close to the surface of the skin without many large nerves positioned nearby.

Minute quantities of blood may be taken by fingersticks sampling and collected from infants by means of a heel stick or from scalp veins with a winged infusion needle.

Phlebotomy (incision into a vein) is also the treatment of certain diseases such as hemochromatosis and primary and secondary polycythemia.


Video Venipuncture



Equipment

There are many ways in which blood can be drawn from a vein. The best method varies with the age of the patient, equipment available and tests required.

Most blood collection in the US, UK and Hong Kong is done with an evacuated tube system, (two common systems are Vacutainer (Becton, Dickinson and company) and Vacuette (Greiner Bio-One GmbH). The equipment consists of a plastic adapter, a.k.a tube or needle holder/ hub, a hypodermic needle and a vacuum tube. Under certain circumstances, a syringe may be used, often with a butterfly needle, which is a plastic catheter attached to a short needle. In the developing world, the evacuated tube system is the preferred method of drawing blood


Venipuncture with evacuated or vacuum tubes

Evacuated tubes were first marketed by U.S. company BD (Becton, Dickinson and Company) under the trade name Vacutainer tubes. Today, many companies sell vacuum tubes as the patent for this device is now in the public domain. These tubes are manufactured with a specific volume of gas removed from the sealed tube. When a needle from a hub or transfer device is inserted into the stopper, the tube's vacuum automatically pulls in the required volume of blood.

The basic Evacuated Tube System (ETS) consists of a needle, a tube holder, and the evacuated tubes. The needle is attached to the tube holder by the phlebotomist prior to collection, or may come from the manufacturer as one unit. the needle protrudes through the end of the tube holder, and has a needle on each end. After first cleaning the venipuncture site and applying a tourniquet, the phlebotomist uncaps the needle attache to the tube holder, inserts the needle into the vein, then slides evacuated tubes into the tube holder, where the tube's stopper is pierced by the back end of the needle. The vacuum in the tube then automatically draws the needed blood directly from the patient's vein. Multiple vacuum tubes can be attached to and removed in turn from a single needle, allowing multiple samples to be obtained from a single procedure. This is possible due to the multiple sample sleeve, which is a flexible rubber fitting over the posterior end of the needle cannula which seals the needle until it is pushed out of the way. This keeps blood from freely draining out of the back of the needle inserted in the patient's vein, as each test tube is removed and the next impaled. Safety regulations require that needles come equipped with a sheath or safety device to cover the needle after the procedure to prevent accidental needle stick injury.

Fittings and adapters used to fill evacuated tubes from butterfly needle kits and syringes are also available.

There are several needle guages for a phlebotomist to choose from. The most commonly used are as follows: a 21g (green top) needle, a 22g (black top) needle, a 21g (green label) butterfly needle, a 23g (blue label) butterfly needle, and a 25g (orange label) butterfly needle (however this needle is only used in pediatrics or extreme cases as it is so small that it can often result in hemolizing the blood sample). There are also a variety of tube and bottle sizes and volumes for different test requirements.

Additives and order of draw

The test tubes in which blood is collected may contain one or more of several additives. In general, tests requiring whole blood call for blood samples collected in test tubes containing some form of the anticoagulant EDTA. EDTA chelates calcium to prevent clotting. EDTA is preferred for hematology tests because it does minimum damage to cell morphology. Sodium Citrate is the anticoagulant used in specimens collected for coagulation tests. The majority of chemistry and immunology tests are performed on serum, which is produced by clotting and then separating the blood specimen via centrifuge. These specimens are collected in either a non-additive tube or one containing a clotting activator. This clotting activator can interfere with some assays, and so a plain tube is recommended in these cases, but will delay testing. Tubes containing lithium heparin or sodium heparin are also commonly used for a variety of chemistry tests, as they do not require clotting and can be centrifuged immediately after collection. A combination of sodium fluoride and potassium oxalate is used for glucose tests, as these additives both prevent clotting and stop glycolosis, so that blood glucose levels are preserved after collection. another specialty tube is an opaque amber colored tube used to collect blood for light sensitive analytes, such as bilirubin.

Test tubes are labeled with the additive they contain, but the stopper on each tube is color coded according to additive as well. While colors vary between manufacturers, stopper colors generally are associated with each additive as listed below. Because the additives from each tube can be left on the needle used to fill the tubes, they must be drawn in a specific order to ensure that cross contamination will not negatively affect testing of the samples if multiple tubes are to be drawn at once. The "order of draw" varies by collection method. Below in the order of draw generally required for the Evacuated Tube System (ETS) collection method are the most common tubes, listing additive and color:

1. Blood cultures and sterile collections (culture bottles)

2. Sodium citrate (light blue)

3. No additive/ Silica clot activator (red and black stripped or gold SST), (red)

4. Lithium Heparin (Light Green PST)

5. Sodium Heparin (green)

6. K2 EDTA, K3 EDTA (Purple/lavender), (pink), (white PPT)

7. Sodium fluoride and potassium oxalate (grey)

8. Tube for testing trace elements containing EDTA or clot activator or no additive (Navy/royal blue)

9. ACD (yellow) and any other tubes


Maps Venipuncture



Venipuncture in children

Use of lidocaine iontophoresis is an effective method for reducing pain and alleviating distress during venipuncture in pediatric patients. Rapid dermal anesthesia can be achieved by local anesthetic infiltration, but it may evoke anxiety in children frightened by needles or distort the skin, making vascular access more difficult and increasing the risk of needle exposure to health care workers. Dermal anesthesia can also be achieved without needles by the topical application of local anesthetics or by lidocaine iontophoresis. By contrast, noninvasive dermal anesthesia can be established in 5-15 min without distorting underlying tissues by lidocaine iontophoresis, where a direct electric current facilitates dermal penetration of positively charged lidocaine molecules when placed under the positive electrode.

One study concluded that the iontophoretic administration of lidocaine was safe and effective in providing dermal anesthesia for venipuncture in children 6-17 years old. This technique may not be applicable to all children. Future studies may provide information on the minimum effective iontophoretic dose for dermal anesthesia in children and the comparison of the anesthetic efficacy and satisfaction of lidocaine iontophoresis with topical anesthetic creams and subcutaneous infiltration.


Advanced Venipuncture and Injection Arm, White - LF01121U ...
src: www.3bscientific.com


Venipuncture with needle and syringe

Some health care workers prefer to use a syringe-needle technique for venipuncture. Sarstedt manufactures a blood-drawing system S-Monovette that uses this principle. This method can be preferred on elderly patients, oncology patients, severely burned patients, obese patients or patients with unreliable or fragile veins. Because syringes are manually operated, the amount of suction applied may be easily controlled. This is particularly helpful with patients who have small veins that collapse under the suction of an evacuated tube. In children or other circumstances where the quantity of blood gained may be limited it can be helpful to know how much blood can be obtained before distributing it amongst the various additives that the laboratory will require.


Coding for Venipuncture - AAPC Knowledge Center
src: www.aapc.com


Blood cultures

There are times where a patient may require a blood culture collection. The culture will determine if the patient has pathogens in the blood. Normally blood is sterile. When drawing blood from cultures use a sterile solution such as Betadine rather than alcohol. This is done using sterile gloves, while not wiping away the surgical solution, touching the puncture site, or in any way compromising the sterile process. It is vital that the procedure is performed in as sterile a manner as possible as the persistent presence of skin commensals in blood cultures could indicate endocarditis but they are most often found as contaminants. It is encouraged to use an abrasive method of skin preparation. This removes the upper layers of dead skin cells along with their contaminating bacteria. Povidone-iodine has traditionally been used but in the UK a 2% chlorhexidine in 70% ethanol or isopropyl alcohol solution is preferred and time must be allowed for it to dry. The tops of any containers used when drawing a blood culture should also be disinfected using a similar solution. Some labs will actively discourage iodine use where iodine is thought to degrade the rubber stopper through which blood enters the bottle, thus allowing contaminates to enter the container.

The blood is collected into special transport bottles, which are like vacuum tubes but shaped differently. The blood culture bottle contains transport media to preserve any microorganisms present while they are being transported to the laboratory for cultures. Because it is unknown whether the pathogens are anaerobic (living without oxygen) or aerobic (living with oxygen), blood is collected to test for both. The aerobic bottle is filled first, and then the anaerobic bottle is filled. However, if the collection is performed using a syringe, the anaerobic bottle is filled first. If a butterfly collection kit is used, the aerobic bottle is filled first, so that any air in the tubing is released into the oxygen-containing bottle.

Specially designed blood culture collection bottles eliminate the need for either the syringe or butterfly collection method. These specially designed bottles have long necks that fit into the evacuated tubes holders that are use for regular venipuncture collection. These bottles also allow for collection of other blood specimens via evacuated tubes, to be collected without additional venipuncture.

The amount of blood that is collected is critical for the optimal recovery of microorganisms. Up to 10mL of blood is typical, but can vary according to the recommends of the manufacturer of the collection bottle. Collection from infants and children are 1 to 5 mL. If too little blood is collected, the ratio of blood-to-nutrient broth will inhibit the growth of microorganisms. If too much blood is collected from the patient, the patient risks a hospital-induced anemia and the ratio of blood-to-nutrient broth will tilt in the opposite direction, which also is not conductive to optimal growth.

The bottles are then incubated in specialized units for 24 hours before a lab technician studies and/or tests it. This step allows the very small numbers of bacteria (potentially 1 or 2 organisms) to multiply to a level which is sufficient for identification +/-antibiotic resistance testing. Modern blood culture bottles have an indicator in the base which changes color in the presence of bacterial growth and can be read automatically by machine. (For this reason the barcoded stickers found on these bottles should not be removed as they are used by the laboratorys automated systems.)


IV Practice Kit with Phlebotomy / Venipuncture How-to Guide ...
src: images-na.ssl-images-amazon.com


Taking blood samples from animals

Blood samples from living laboratory animals may be collected using following methods:

  • Blood collection not requiring anesthesia:
    • Saphenous vein (rat, mice, guinea pig)
    • Dorsal pedal vein (rat, mice)
  • Blood collection requiring anesthesia (local/general anesthesia):
    • Tail vein (rat, mice)
    • Tail snip (mice)
    • Orbital sinus (rat, mice)
    • Jugular vein (rat, mice)
    • Temporary cannula (rat, mice)
    • Blood vessel cannulation (guinea pig, ferret)
    • Tarsal vein (guinea pig)
    • Marginal ear vein or artery (rabbit)
  • Terminal procedure:
    • Cardiac puncture (rat, mice, guinea pig, rabbit, ferret)
    • Orbital sinus (rat, mice)
    • Posterior vena cava (rat, mice)

The volume of the blood sample collection is very important in experimental animals. All nonterminal blood collection without replacement of fluids is limited up to 10% of total circulating blood volume in healthy, normal, adult animals on a single occasion and collection may be repeated after three to four weeks. In case repeated blood samples are required at short intervals, a maximum of 0.6 ml/kg/day or 1.0% of an animal's total blood volume can be removed every 24 hours. The estimated blood volume in adult animals is 55 to 70 ml/kg body weight. Care should be taken for older and obese animals. If blood collection volume exceeds more than 10% of total blood volume, fluid replacement may be required. Lactated Ringer's solution (LRS) is recommended as the best fluid replacement by National Institutes of Health (NIH). If the volume of blood collection exceeds more than 30% of the total circulatory blood volume, adequate care should be taken so that the animal does not suffer from hypovolemia.


Deep Vessel Venipuncture Pad with Nerves (4x8x2) | Simulab Corporation
src: www.simulab.com


Blood alcohol tests

It is generally not advisable to use isopropyl alcohol to cleanse the venipuncture site when obtaining a specimen for a blood alcohol test. This has been related largely to the potential legal implications associated with use of alcohol based cleaners that could theoretically impact analysis. Numerous police alcohol collection kits have been marketed that incorporate a sodium fluoride/potassium oxalate preservative and non-alcohol based cleansing agents to ensure proper collection. Using soap and hot water or a povidone iodine swab are advisable alternatives to isopropyl alcohol in this case.


Venipuncture, Preparing An Injection Stock Photo - Image: 40067580
src: thumbs.dreamstime.com


See also

  • Arterial blood is taken from an artery instead of a vein.
  • Blood donation
  • Fingerstick
  • Neonatal heel prick
  • Phlebotomist
  • Vacutainer

How to apply a tourniquet for clinical skills- cannulation and ...
src: i.ytimg.com


References


Deep Vessel Venipuncture Pad (4x8x2) | Simulab Corporation
src: www.simulab.com


External links

  • Phlebotomy details

Source of the article : Wikipedia

Comments
0 Comments